What sensors detect smoke? The various technologies used in smoke detectors have very significant implications. Smoke alarms warn you swiftly about a smoke or fire emergency. For instance, photoelectric smoke detectors are perfect for identifying smoke from smoldering fires, whereas ionization smoke alarms identify smoke from rapid, flaming fires. You'll want to be alerted as soon as possible, whether a smoldering fire or a flaming fire.
At Therrell Alarm Protection Service, we aim to help you grasp the technology that keeps you safe so you can make the best choice when safeguarding your home and family from a fire.
Smoke detectors are of two types: ionization and photoelectric. They warn about fires in two ways, and methods with a heat sensor are used, too. They run on a 9-volt battery, a lithium battery, or house wiring that's 120 volts.
Ionization detectors include an ionization chamber and a source of ionizing radiation. The ionizing radiation source is a small americium-241 (maybe 1/5000th of a gram), emitting alpha particles (helium nuclei).
The ionization chamber contains two plates with a separation of about one centimeter. A battery provides a voltage to the plates, making one positively charged and the other negatively charged. Alpha particles always released by americium knock electrons off the atoms in the air, ionizing the nitrogen and oxygen atoms in the chamber.
The oxygen and nitrogen atoms that are positively charged are drawn to the negative plate, and the positive plate attracts electrons, producing a small, steady electric current. When smoke enters the ionization chamber, the particles stick to the ions and neutralize them so they do not reach the plate. The reduction in current between the plates sets off the alarm.
Recommended for use in:
Ionization smoke detectors check for ions or charged particles in the air. If smoke goes into the device, it creates an electrical imbalance. When particles from burning materials enter the detector, they block the current flow, triggering an alarm when the current is too low.
Ionization smoke detectors respond well to fast-flaming fires and are best suited for locations containing highly combustible materials such as cooking fat, paint, or flammable liquids. They are inexpensive and the most popular type of smoke detector in the United States.
Ionization detectors typically respond faster than photoelectric detectors, yet they often cannot tell the difference between smoke and steam, leading to false alarms sometimes.
In one photoelectric gadget, smoke can interfere with a light beam. Here, the decrease in light hitting a photocell triggers the alarm. In the most typical type of photoelectric device, light is instead scattered by smoke particles onto a photocell, causing an alarm to start. This detector type has a T-shaped chamber with an LED that sends a light beam across the T's horizontal bar.
A photocell at the bottom of the T's vertical base produces a current when light hits it. When there is no smoke, the light beam goes straight across the top of the T without hitting the photocell placed at a right angle beneath the beam. If smoke appears, the light gets scattered by smoke particles, and part of it is sent down the vertical part of the T to hit the photocell. When enough light reaches the cell, the current sets off the alarm.
Recommended for use in:
Optical beam smoke detectors, similar to aspirating smoke detectors, detect smoke over a large open area instead of just one spot and are extremely sensitive to diluted smoke at high levels, such as in spaces with high ceilings. They cost a lot to install and are very good at spotting bigger particles of smoke from slow-burning, smoky fires, like smoldering foam-filled upholstery or overheated PVC wiring.
The detectors work by using light to block the sensor's view. They point the light towards a sensing chamber at an angle. The sensors operate by using light blocked by directing a beam of light into a chamber next to the sensor. If smoke enters the chamber, it bounces light onto the sensor, setting off an alert.
There are dual-path versions with a sender and a recipient on one side and a reflector on the other. Beam detectors are common in structures where putting in single-point smoke sensors would be too costly or tricky.
Smoke sensors come in two types: ionization and photoelectric detectors. For a smoke detector to be UL-certified, it must pass the same test regardless of its type. Ionization detectors are faster at detecting fires with small particles, while photoelectric ones are quicker at detecting smoldering fires. High humidity or steam can cause condensation on either type's sensor or circuit board, triggering the alarm. Ionization detectors are cheaper compared to photoelectric ones. Yet, certain users intentionally turn them off since they often trigger false alarms during regular cooking because they're highly sensitive to tiny smoke particles.
Nevertheless, ionization detectors possess inherent safety that is not found in photoelectric detectors. As the battery weakens in an ionization detector, the ion flow decreases, prompting the alarm to go off and signaling it's time to replace the battery before the detector loses effectiveness. Additional batteries can be employed for photoelectric detectors.
Do you want to learn more about smoke detectors and fire alarms? Please reach out to us today!
The peak time for home fires is between 10 p.m. and 6 a.m., when most people are asleep.
Fire victims are usually overcome while they sleep, and they die from smoke inhalation and carbon monoxide poisoning, not from burns. Studies have shown that when a fire starts, a person has an average of less than 4 minutes and sometimes as little as 1 minute to escape the disabling effects of smoke and poisonous gases. Those same gases dull your senses while you sleep, making a safe escape even more difficult.
Smoke detectors are the leading lifesaving device in home fire safety. Most fatal home fires occur at night while people are asleep, and smoke detectors can alert sleeping residents before they become fire victims.
Maintaining and installing smoke detectors in your house can decrease your risk of death in a fire by 50%. You should place smoke alarms on each floor of your house and in each bedroom where someone sleeps. It's good to test smoke alarms every month, and you should change the batteries at least once a year. It's even better to swap out the batteries once you adjust your clocks for daylight-saving time in spring and autumn.
Don't ever take the battery from your smoke alarm. 96% of U.S. homes have smoke detectors. However, 23% of the smoke detectors do not work because of dead or missing batteries. Smoke detectors provide early warning of a fire. If you use this time well, it could save you. Yet, don't wait for the smoke detector to beep before making an escape plan.
The standard recommendations for smoke detector placement include having at least one on each level of a structure, such as on the main floor and in a basement. The recommended placement is near the top of the area if there is a high vaulted ceiling. However, an in-person assessment from an experienced professional can give you the specific information you need to protect your home or business best.
According to the NFPA, smoke detectors can last up to 10 years from manufacture. The date of manufacture is on the back of your smoke alarm. Remember that the date of purchase isn't the date of manufacture, so even if you have just purchased new alarms, you should check the date.
Remembering to do something ten years from now is hard, so check the date every year. Please write down this date somewhere you will see it or put a reminder on your phone or email calendar.